EMC harmonic current cannot pass.

Hardware design
10月 23, 2020 by Rolando 393

In the circuit shown in the figure, the load is a heating tube and the diode is used for half-wave rectification, but the EMC harmonic current test cannot be passed. What kind of improvement is needed on the circuit?

すべてのコメント

user image

Ryann ポストする October 23, 2020

Pure resistive load, there should be no interference. The host should check whether there is interference on the 220 terminal, such as frequency converter, fluorescent lamp, etc.

0
  • Rolando

    Rolando ポストする October 23, 2020

    The circuit has no other load. Will it be related to the power? My power is 1500W before diode rectification.

  • 返信するにはログインする必要があります。 サインイン | 登録する

user image

Ryann ポストする October 23, 2020

It is possible, but I feel like it is the electromagnetic interference generated at the switch contact. If the contact is oxidized, arc ablation can easily cause this situation.