RFQ/BOM 0 サインイン / 登録する

所在地を選択してください

ユーザーイメージ

The half-bridge circuit analyzes the current.

Hardware design
12月 03, 2020 by Garret 906

This is the current circuit, and the current waveform of the upper tube I measured is shown in the figure below:

1 is the upper tube current, 4 is the upper tube drive, 2 is the lower tube current,

Channels 2, 3 are the switching tube DS voltages respectively


Now that the voltage cannot be increased, the tube can't stand it when it is about 400V, and the current waveform is a bit different from the simulation. What could be the reason?

すべてのコメント

user image

Denis ポストする December 3, 2020

Is there a short circuit in the transformer?

0
  • Garret

    Garret ポストする December 3, 2020

    What does a transformer short circuit mean? Didn't the original vice side achieve isolation?

  • 返信するにはログインする必要があります。 サインイン | 登録する

user image

Magnus ポストする December 3, 2020

It feels like a short circuit between turns.

0
user image

Candace ポストする December 3, 2020

Whether the transformer has magnetic flux saturation.

0

答えを書く

返信するにはログインする必要があります。 サインイン | 登録する